The NDB1L-32C-32-120V is a DIN rail mounted ground fault circuit breaker that
combines overload, short-circuit, and 30mA earth-leakage protection in one
compact device. Rated 32A at 120VAC, it uses a C trip curve and provides a
4.5kA interrupting rating for industrial equipment and control applications.
The breaker includes 1 pole plus neutral, a push-to-test button, visual trip
indication, finger-safe screw clamp terminals, and 35mm DIN rail mounting.
It is UL1053 Recognized for equipment ground-fault protection applications.
WHAT PROBLEM DOES THIS SOLVE?
Standard circuit breakers protect wiring and equipment against overloads and
short circuits but do not necessarily detect lower-level current leaking to
ground.
The NDB1L-32C-32-120V adds 30mA earth-leakage detection to conventional
overcurrent protection. If leakage exceeds the specified threshold, the
breaker opens the circuit to help protect equipment and reduce the risk of
damage caused by ground faults.
IMPORTANT APPLICATION NOTE
This is a 30mA equipment ground-fault protection device. It should not be
marketed as Class A personnel GFCI protection.
Class A GFCI protection used for personnel protection operates at a
substantially lower ground-fault threshold. The 30mA NDB1L is intended for
equipment ground-fault protection under UL1053.
KEY FEATURES & BENEFITS
• Combines Overload, Short-Circuit, and Ground-Fault Protection
• 32A Rated Current for 120VAC Equipment and Control Circuits
• 30mA Earth-Leakage Trip Threshold for Equipment Protection
• C Trip Curve Accommodates Moderate Equipment Starting Current
• 4.5kA Interrupting Rating for Industrial Circuit Protection
• 1 Pole + Neutral Configuration Disconnects the Protected Circuit
• Push-to-Test Button Allows Periodic Ground-Fault Function Testing
• Visual Trip Indicator Helps Identify a Tripped Breaker
• 35mm DIN Rail Mounting Simplifies Control Panel Installation
• UL1053 Recognized for Equipment Ground-Fault Protection
APPLICATIONS
• Industrial Control Panels
• OEM Machinery
• Factory Automation Equipment
• Machine Control Circuits
• HVAC Equipment
• Pumps and Process Equipment
• Industrial Equipment Requiring Earth-Leakage Protection
• UL1053 Equipment Ground-Fault Protection Applications
WHY CHOOSE THIS PRODUCT?
The NDB1L-32C-32-120V combines three protection functions in one DIN rail
device: overload protection, short-circuit protection, and 30mA earth-leakage
detection. This can simplify panel design compared with using separate
overcurrent and ground-fault protection components.
IMPORTANT APPLICATION NOTE
This is a 30mA equipment ground-fault protection device. It should not be
marketed as Class A personnel GFCI protection.
Class A GFCI protection used for personnel protection operates at a
substantially lower ground-fault threshold. The 30mA NDB1L is intended for
equipment ground-fault protection under UL1053.
WHY ASI?
U.S. inventory, fast shipping, technical support, and 25+ years of industrial
automation experience. That's the ASI way.
In Stock (420)
Specifications
Circuit Breakers
Trip Curve
C Trip Curve (Medium)
Breaker Mounting
35mm DIN Rail
Others
Amperage
32 Amps
Your Dynamic Snippet will be displayed here...
This message is displayed because youy did not provide both a filter and a template to use.
Recently Viewed Products:
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.